CLI Commands
2-13
config
Parameters
This command has four parameters.
NOTE:
The interval value is a fixed length amount of time. This interval is
not a rolling window interval.
name
The name of the fencing policy.
typeNumber
This must be entered as a number that
corresponds to an entry in the table
shown below.
limit
The count of fencing violations that must
occur within the specified period in order
for a port to be automatically disabled.
Acceptable values are in the range of
1-255.
You may also enter
default
for this
argument, which will set the default limit
value for this fencing policy type.
period
The number of seconds in which the
violation count must equal or exceed the
threshold limit in order for a port to be
fenced.
You may also enter
default
for this
argument, which will set the default
period for this fencing policy type.
Type
Number
Policy Type
Default Limit
Value
Default Period Value
1
Protocol Errors
5
300 seconds
Type
Number
Policy Type
Limit Value Range
Period Value Range
1
Protocol Errors
1 - 255
60 - 1800 seconds
Summary of Contents for Enterprise Operating System
Page 1: ...Enterprise Operating System Command Line Interface User Manual P N 620 000134 720 REV A...
Page 4: ...Enterprise Operating System Command Line Interface User Manual iv...
Page 12: ...Enterprise Operating System Command Line Interface User Manual xii Contents...
Page 14: ...xiv Enterprise Operating System Command Line Interface User Manual Tables...
Page 20: ...xx Enterprise Operating System Command Line Interface User Manual Preface...
Page 44: ...1 1 24 Enterprise Operating System Command Line Interface User Manual Backup and Restoration...
Page 240: ...2 2 196 Enterprise Operating System Command Line Interface User Manual show...
Page 290: ...A A 50 Enterprise Operating System Command Line Interface User Manual...
Page 300: ...B B 10 Enterprise Operating System Command Line Interface User Manual...
Page 328: ...Enterprise Operating System Command Line Interface User Manual i 10 Index...