Engine General Information and Diagnosis: Bi-Fuel LPG model 1A-28
LPG Control Module
When any of the following DTCs is detected, LPG control module enters fail-safe mode as long as malfunction
continues to exist but that mode is canceled when LPG control module detects normal condition.
NOTE
When LPG control is stopped by fail-safe control, LPG warning light blinks.
P0122
)
Throttle / Pedal Position Sensor / Switch “A”
Circuit Low
• ECM controls engine assuming that throttle opening
angle is about 20°.
• ECM stops A/F feedback (closed-loop) control.
P0123
)
Throttle / Pedal Position Sensor / Switch “A”
Circuit High
P0130
)
O2 Sensor Circuit
ECM stops EVAP canister purge valve control.
P0327
)
Knock Sensor1 Circuit Low
• ECM stops knock control.
• Ignition timing is retarded.
P0328
)
Knock Sensor1 Circuit High
P0335
)
Crankshaft Position Sensor “A” Circuit
—
P0336
)
Crankshaft Position Sensor “A” Circuit Range /
Performance
P0340
)
Camshaft Position Sensor “A” Circuit
• ECM controls fuel cut at 4,000 rpm.
• ECM stops knock control.
• Ignition timing is retarded.
P0341
)
Camshaft Position Sensor “A” Circuit Range /
Performance
P0443
)
Evaporative Emission System Purge Control
Valve Circuit
—
P0480
)
Fan1 Control Circuit
P0500
)
Vehicle Speed Sensor “A”
• ECM controls engine assuming that vehicle speed is
0 km/h (0 mph).
• ECM stops ISC feedback control.
P0505
)
Idle Air Control System
—
P0532
)
A/C Refrigerant Pressure Sensor “A” Circuit
Low
ECM stops A/C control.
P0533
)
A/C Refrigerant Pressure Sensor “A” Circuit
High
P0560
)
System Voltage
—
P0601
Internal Control Module Memory Check Sum
Error
P0602
Control Module Programming Error
P0616
)
Starter Relay Circuit Low
P0617
)
Starter Relay Circuit High
P0620
)
Generator Control Circuit
ECM controls engine assuming that duty of generator
field coil is about 50%.
P0625
)
Generator Field / F Terminal Circuit Low
P0626
)
Generator Field / F Terminal Circuit High
DTC
DTC name
Fail-safe operation
DTC
DTC name
Fail-safe operation
P0005
Fuel Shutoff Valve “A” Control Circuit / Open
• LPG control module closes shut off valve of LPG tank
valve.
• LPG control module stops LPG control and then shifts
operating mode to “Petrol MODE”.
P0007
Fuel Shutoff Valve “A” Control Circuit High
P0182
Fuel Temperature Sensor “A” Circuit Low
LPG control module controls engine assuming that LPG
temperature is 50 °C (122 °F).
P0183
Fuel Temperature Sensor “A” Circuit High
P0192
Fuel Rail Pressure Sensor “A” Circuit Low
LPG control module controls engine assuming that LPG
fuel pressure is MAP (Manifold Absolute Pressure) + 80
kPa.
P0193
Fuel Rail Pressure Sensor “A” Circuit High
P0201
Injector Circuit / Open - Cylinder 1
—
P0202
Injector Circuit / Open - Cylinder 2
—
P0203
Injector Circuit / Open - Cylinder 3
—
P0601
)
Internal Control Module Memory Check Sum
Error
—
P0602
)
Control Module Programming Error
—
Summary of Contents for Wagon R
Page 2: ......
Page 32: ...0B 5 Maintenance and Lubrication ...
Page 184: ...1J 3 Charging System ...