© 2012 Mahindra & Mahindra Ltd.
`
P1630
ECU EEPROM ERROR
EEPROM MONITORING
EEPROM (Electrically Erasable Programmable Read Only Memory) is a storage device inside the EMS ECU.
EEPROM can be flashed , read and written
DTC INFORMATION
PROBABLE CAUSES OF FAILURE
NORMAL OPERATION
Ignition ON
EEPROM can be flashed, read & written
DTC DETECTING CONDITIONS
Ignition ON
EMS ECU supply voltage 8-16V
The block cannot be written more than 3 times from the
EEPROM
DTC REACTIONS
Engine check lamp continuously ON.
EMS ECU Switches OFF
HEALING CONDITION
Ignition Off/On
Malfunctioning EMS ECU
61