P06A1
SHORT CIRCUIT TO GROUND ERROR ON POWER STAGE FOR THE COMPRESSOR
AC COMPRESSOR POWER STAGE
The AC Compressor is controlled by the EMS ECU under the feedback of the temperature sensing unit in
the HVAC system and pressure sensors measuring the pressure of the refrigerant flow in the air
conditioning circuit. The ECU monitors the status of the Power Stage (Actuator) of the Compressor Clutch
for monitoring
hardware errors such as short circuit to battery, Short circuit to ground and Open load.
DTC INFORMATION
PROBABLE CAUSES OF FAILURE
NORMAL OPERATION
Ignition ON
EMS ECU switches ON the compressor once it recieves AC
switch ON signal thru thermoamplifier via high low
pressure switch
No malfunction detected by EMS ECU in the AC compressor
power circuit
DTC DETECTING CONDITIONS
Ignition ON
EMS ECU supply voltage 8-16V
Short to ground is detected in AC compressor relay control
circuit
DTC REACTIONS
AC Compressor Shuts OFF
HEALING CONDITION
Ignition Off/On
Short to Ground in AC
compressor relay control
wire
Faulty AC compressor
relay
Faulty EMS ECU