P0562
BATTERY VOLTAGE LOW ERROR
BATTERY
The Electronic Control Unit continuosly monitors the battery voltage for its proper functioning.The
normal operating voltage for EMS ECU is 8- 16 V.
.
DTC INFORMATION
PROBABLE CAUSES OF FAILURE
NORMAL OPERATION
Ignition ON
EMS ECU receives a supply voltage of 8-16V
DTC DETECTING CONDITIONS
Ignition ON
The supply voltage to EMS ECU is less than 8 V for few
seconds.
DTC REACTIONS
Engine Check lamp will be continuously ON
EMS ECU switches OFF
HEALING CONDITION
Ignition Off/On
Faulty Battery
Faulty Charging System
Open/Short in EMS ECU
ignition power wire
Malfunctioning EMS ECU