DIAGNOSTIC MANUAL MAN-00201
QUANTO
EMS
SEP 2012/Rev 1
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution
© 2012 Mahindra & Mahindra Ltd.
`
STEP 1
Connect the smart tester
Turn the ignition ON
Initialise the diagnostic tool
Record the DTC and clear
Turn ignition OFF
Turn ignition ON
Verify if P170D is present?
Is P170D present?
Intermittent problem exists
Refer the intermittent problem
inspection procedure
STEP 2
Ignition OFF
Ensure the starter relay
is fixed properly in the
connector of the relay box
Remove the starter relay
Check the functioning of relay by
providing 12V to terminal 86
and ground to terminal 85
Is a clicking sound
heard?
Replace the starter relay with a
new one
Clear the DTC and verify
NO
NO
YES
YES
Examine the short to battery of
of starter relay control wire
from EMS ECU
Replace the wiring harness
Clear the DTC and verify
P 170D
324