DIAGNOSTIC MANUAL MAN-00201
QUANTO
EMS
SEP 2012/Rev 1
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution
© 2012 Mahindra & Mahindra Ltd.
`
STEP 1
Connect the smart tester
Turn the ignition ON
Initialise the diagnostic tool
Record the DTC and clear
Turn ignition OFF
Turn ignition ON
Verify if P170E is present?
Is P170E present?
Intermittent problem exists
Refer the intermittent problem
inspection procedure
STEP 2
Ignition OFF
Remove the starter relay
Check the continuity between
pin 1 of the starter relay
seating (C70) and battery
ground
Is the continuity
exists?
Examine the short circuit of
starter relay control signal wire
with ground
Replace the wiring harness
Clear the DTC and verify
Suspect EMS ECU malfunction
Replace EMS ECU with a new
one.
Check and verify for any new
DTC’s
NO
YES
YES
NO
P 170E
326