STEP 1
Connect the smart tester
Turn the ignition ON
Initialise the diagnostic tool
Record the DTC and clear
Turn ignition OFF
Turn ignition ON
Verify if P06A0 is present?
Is P06A0 present?
Intermittent problem exists
Refer the intermittent problem
inspection procedure
STEP 2
STEP 3
Ignition OFF
Ensure the compressor relay is
fixed properly in the connector
of the ECU fuse box
Remove the AC compressor
relay
Check the functioning of relay by
providing 12V to terminal 86
and ground to terminal 85
Is a clicking sound
heard?
Replace the AC compressor
relay with a new one
Clear the DTC and verify
Is the value = Vbat?
Ignition OFF
Remove the AC compressor
relay
Check the proper functioning of
10 A fuse (F38) and 10 A fuse
(F16)
Ignition ON
Check the voltage between pin
5 of the AC compressor relay
seating (C107) and battery
ground
Check the voltage between pin
3 of the AC compressor relay
seating (C107) and battery
ground
NO
NO
NO
YES
YES
YES
Examine the open/short circuit
of AC compressor relay power
wire from EMS main relay and
from ignition switch
Replace the wiring harness
Clear the DTC and verify
Go to STEP 4
P 06A0