DIAGNOSTIC MANUAL MAN-00201
QUANTO
EMS
SEP 2012/Rev 1
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution
© 2012 Mahindra & Mahindra Ltd.
`
P0563
BATTERY VOLTAGE HIGH ERROR
BATTERY
The Electronic Control Unit continuosly monitors the battery voltage for its proper functioning.The
normal operating voltage for ECU is 8- 16 V.
.
DTC INFORMATION
PROBABLE CAUSES OF FAILURE
NORMAL OPERATION
Ignition ON
EMS ECU receives a supply voltage of 8-16V
DTC DETECTING CONDITIONS
Ignition ON
The supply voltage to EMS ECU is more than 16.8 V for few
seconds.
DTC REACTIONS
Engine Check lamp will be continuously ON
EMS ECU switches OFF
HEALING CONDITION
Ignition Off/On
Faulty Battery
Faulty Charging System
Malfunctioning EMS ECU
40