P0234
BOOST PRESSURE CONTROLLER DEVIATION BELOW MINIMUM LIMIT
DTC INFORMATION
PROBABLE CAUSES OF FAILURE
NORMAL OPERATION
Ignition ON
The permissible negative control deviation of the closed loop
boost pressure control is with in the limit
DTC DETECTING CONDITIONS
Ignition ON
EMS ECU supply voltage 8-16V
Negative control deviation of the closed loop boost pressure is
below the minimum limit.
DTC REACTIONS
EGR Shuts OFF
Engine Check lamp continuously ON
HEALING CONDITION
Ignition Off/On
Blocked vent hose of boost
pressure actuator
Faulty boost pressure
actuator
CORRECTIVE ACTION
Check for any blockage in vent hose of boost pressure actuatorand if found , rectify it
If the problem still exists , replace the boost pressure actauator with new one
262