87
BA023001-en
X13 MAHA
The X13 MAHA interface is primarily used to connect a MAHA access point so that the
test bench can be reached via the access point's WiFi. The network interface at X13
MAHA tries to obtain IP addresses via DHCPv4/v6 for 30 seconds when the central
module is started (or a cable is plugged in). If no DHCP server responds during this
time, i.e. obtaining the addresses fails, then the central module itself acts as a DHCPv4
server, assigns itself the address 192.168.201.1
and distributes IP addresses in the
network in which the X13 MAHA interface is located.
This configuration cannot be changed. On the one hand, this ensures that the MAHA
Access Point functions correctly with this interface, and on the other hand, it allows
the network configuration of the X12 EXT interface to be performed via the X13 MAHA
port.
6.8.3
Adjusting the brake force
See section “Calibration / Adjustment”.
6.8.4
Test bench settings
Parameter settings for the test bench can be made here. The respective parameter,
the default value and the last stored value are displayed. In the column on the far
right, a desired value can be entered, which is accepted by pressing the "Save" button.
Summary of Contents for CONNECT Series
Page 19: ...19 BA023001 en 2 3 2 Set up diagram Set up diagram I ...
Page 20: ...20 BA023001 en Set up diagram II ...
Page 22: ...22 BA023001 en 2 4 1 Wiring diagram ...
Page 23: ...23 BA023001 en 2 4 2 Control cabinet structure Basic variant ...
Page 24: ...24 BA023001 en 2 4 3 Control cabinet structure Full equipment ...
Page 25: ...25 BA023001 en ...
Page 53: ...53 BA023001 en ...
Page 138: ...138 BA023001 en 13 Annex 13 1 Naming convention ...