A network hub is recommended for commissioning with the "LAN connection"
variant. The network hub enables the simultaneous connection of the analogue
display and the service PC for coupling with the control board ZM (central module)
at the X13 port.
•
Alternatively, the RJ45 socket X12 "External" can be used on the control board ZM
(central module), if not assigned.
•
If a network socket of the control board is connected to the house network, the
analogue display can also be connected to the test bench via the house network.
Coupling (pairing) with central module
•
Briefly press the pairing button on the analogue display.
All three LEDs light up permanently and in the "External devices" view the ana-
logue display has the status "Pairing active".
•
Click the "Pair devices" button.
•
Wait until the status of the display is "Connected".
•
Exit the coupling mode of the central module by clicking the "Stop coupling" but-
ton.
Result
The analogue display is initialised ("LED small measuring range" is permanently lit) and
in the "External devices" view the analogue display has the status "Connected".