47LLC OPERATING MANUAL EM-9505-B Rev.4
18.2 RETAINING MAX AND MIN VALUEs
MAX and MIN values can be confirmed while in Measuring Mode. Each time pressing Max/Min button during Measur-
ing Mode, the indication is switched in the order of MAX value to MIN value and back to original indication. Max. value is
updated while it is indicated. Min. value is updated while it is indicated.
■
MAX AND MIN VALUEs
MAX and MIN values are updated while in measuring.
(1) The internal memory is reset for approx. 1 second after the power is on, and the unit starts to measure MAX and MIN
values.
(2) Hold down Max/Min button for 1 second or more to reset the MAX and MIN values and then the unit starts to measure
MAX and MIN values again.
(3) The internal memory is reset for approx. 1 second after the power is off and on again, and then the unit starts to meas-
ure MAX and MIN values again.
Display value
MAX value
MIN value
Measurement
Reset
Reset
Reset
Measuring
(1)
(2)
(3)
Measuring
Holding
down
Approx. 1 sec.
Approx. 1 sec.
Power
ON
ON
OFF
1 sec.
Max/Min