47LLC OPERATING MANUAL EM-9505-B Rev.4
■
sHIFTING THROUGH sETTING PARAMETERs
(1) Parameter shifting in Scaling Setting Mode
In Scaling Setting Mode, pressing Alarm/
↓
button shifts one parameter to the next (clockwise in the following figure).
Pressing Scale/
↑
button shifts one to the previous (counterclockwise).
NOTE
•
The display depends on the input strain gauge code and settings. The above displays show default values with the
input strain gauge code ‘S2’.
•
Hold down Alarm/
↓
or Scale/
↑
button for 1 second or more to return to Measuring Mode from each parameter.
Measuring Mode
Excitation voltage
Display scaling value A
Input scaling value B
Display scaling value B
Decimal point position
for ≥ 3 sec.
Hold down Scale/
↑
Input type
Analog output function mode
*
1
Analog output 0% adjustment
*
1
Analog output 100% adjustment
*
1
*
1 Disabled with no-DC-output type.
Input scaling value A
Scaling Setting Mode
Load ratio
Tare adjustment