232
47DAC OPERATING MANUAL EM-9518-B Rev.4
■
INPUT SPECIFICATIONS
Frequency
40 Hz – 1 kHz
Overload capacity
200% of rating for 10 sec., 110% of rating continuous
AC voltage
Input type: 0.2V
Measuring range
0 – 0.2 V
Operational range
0 – 0.22 V
Input impedance
1 MΩ minimum
Input type: 2V
Measuring range
0 – 2 V
Operational range
0 – 2.2 V
Input impedance
1 MΩ minimum
Input type: 20V
Measuring range
0 – 20 V
Operational range
0 – 22 V
Input impedance
1 MΩ minimum
Input type: 200V
Measuring range
0 – 200 V
Operational range
0 – 220 V
Input impedance
1 MΩ minimum
AC current
Input type: 0.2MA
Measuring range
0 – 0.2 mA
Operational range
0 – 0.22 mA
Input impedance
Approx. 100 Ω
Input type: 2MA
Measuring range
0 – 2 mA
Operational range
0 – 2.2 mA
Input impedance
Approx. 100 Ω
Input type: 20MA
Measuring range
0 – 20 mA
Operational range
0 – 22 mA
Input impedance
Approx. 1 Ω
Input type: 200MA
Measuring range
0 – 200 mA
Operational range
0 – 220 mA
Input impedance
Approx. 1 Ω
■
DC OUTPUT SIGNAL SPECIFICATIONS
DC voltage
Analog output type:
0-5V
Output range
0 – 5 V
Operational range
-0.5 – +5.5 V
Load resistance
2000 Ω minimum
Analog output type: 5V
Output range
±5 V
Operational range
-6 – +6 V
Load resistance
4000 Ω minimum
Analog output type: 10V
Output range
±10 V
Operational range
-12 – +12 V
Load resistance
8000 Ω minimum
DC current
Analog output type:
0-20MA
Output range
0 – 20 mA
Operational range
-2 – +22 mA
Load resistance
400 Ω maximum
Analog output type:
4-20MA
Output range
4 – 20 mA
Operational range
2.4 – 21.6 mA
Load resistance
400 Ω maximum