41
47DAC OPERATING MANUAL EM-9518-B Rev.4
2.2 BASIC SETTING OPERATION AND INSTRUCTIONS
This section describes basic operation and instructions when setting parameters.
2.2.1 BASIC SETTING OPERATION
Parameters can be grouped into three setting types, “numerical value setting”, “setting value selection” and “decimal point
position selection”. Basic operation of each type is as shown below.
■
NUMERICAL VALUE SETTING
1
Press Shift button to shift the display into the setting standby
mode.
• The most significant digit starts blinking.
2
Press Shift and Up buttons to set a numerical value.
• Press Shift button to go to the next digit.
• Press Up button to change the blinking value.
3
Press Alarm/
↓
or Scale/
↑
button to apply the new setting.
• The next or previous parameter setting is indicated.
NOTE
■
SHIFTING DIGITS
Each time pressing Shift button, the blinking digit moves to the right.
■
SETTING A NUMERICAL VALUE
• Each time pressing Up button, the numeral is incremented by 1. In setting an alarm setpoint, the indication following ‘9’
will be ‘-’.
• The negative sign (-) must be set to the 6th digit. For example, set ‘-004.00’ instead of ‘-4.00’.
・・・・・
*
6th digit
*
1 Display depands on the specifications and settings.