36.4.4 ADVANCED SETTING MODE
■
LOCKOUT ‘LV0’ (COMPLETELY UNLOCK ADVANCED SETTING MODE)
NOTE
• With the event trigger mode set to “normal”, the ON timing delay and OFF timing delay are disabled.
• With the event trigger mode set to “sampling hold”, the OFF timing delay is disabled.
• With the low-end cutout set to OFF, the low-end cutout value setting is locked.
for ≥ 3 sec.
+
for ≥ 1 sec.
Measurement
started
Measurement
stopped
Measuring Mode
or
Advanced Setting Mode
Event trigger mode
NORMAL (normal)
S-HLD (sampling hold)
P-HLD (peak hold)
B-HLD (valley (bottom)
hold)
PP-HLD (peak-to-peak
hold)
ON timing delay
0.0 – 999.9 sec.
Startup timer
0.0 – 99.9 sec.
OFF timing delay
0.0 – 999.9 sec.
Averaging type
MOVING (moving average)
SIMPLE (simple average)
OFF, 2, 4, 8, 16, 32, 64,
128, 256, 512
Averaging time
OFF (low-end cutout OFF)
ON (low-end cutout ON)
ABS (absolute value
low-end cutout ON)
Low-end cutout
Low-end cutout value
Display color
000 – 999
GRN-R (green (normal) to
red (alarm))
GRN (green)
RED-G (red (normal) to
green (alarm))
RED (red)
00 (automatic return
disabled)
1 – 99 sec.
Automatic return time
to Measuring Mode
0 – 99 sec.
Transition time to
Lockout Setting Mode
0.0 – 99.9 sec.
Display refreshing
rate
OFF (automatically
reset)
ON (manually reset)
Manual sub display
reset
P output
OFF (no P output)
LL (alarm setpoint LL)
L (alarm setpoint L)
H (alarm setpoint H)
HH (alarm setpoint HH)
Latching alarm
OFF (no latching)
OUT (output latched /
measuring continued)
ALL (output latched /
measuring stopped)
Alarm power ON
delay
0.0 – 999.9 sec.
Standby sequence
OFF
(output immediately at
the startup)
ON
(output standing by
until the input enters
P zone)
Scaling error
ON (alarm trip action
valid at over-range)
OFF (no alarm trip
action at over-range)
OFF, 2, 5, 10
Round off low-digit
readingtime
NORMAL (measured
value)
MAX (MAX value)
MIN (MIN value)
Display reading type
High-pass filter
OFF, ON
1 (dark) to 3 (bright)
Backlight brightness
1 (low) to 10 (high)
LCD contrast
Bank switching
OFF (disabled)
KEY (enabled via the
front button control)
COM (enabled via
Modbus communica-
tion)
REQ input logic
ON
(request valid at ON)
OFF
(request valid at OFF)
ON (data valid at ON)
OFF (data valid at
OFF)
DAV output logic
ON (negative logic
open collector)
OFF (positive logic
open collector)
DATA output logic
ON (valid at ON)
OFF (valid at OFF)
Status output logic
Indicating firmware
version
Version indication
Selectable only with the I/O option code ‘6’ or ‘A’ (event trigger input).
*
1
Selectable only with the I/O option code ‘5’ , ‘9’ or ‘A’ (BCD output).
*
2