204
47DAC OPERATING MANUAL EM-9518-B Rev.4
26. FORCING THE PRESENT DISPLAY VALUE TO ZERO
The display value can be forced to 0 while in Measuring Mode. Press Up button during Measuring Mode to shift the pre-
sent display value to zero and to continue measuring in reference to this point. This operation is called Forced Zero. Press
Up button during Forced Zero mode to execute the Forced Zero again, which is called Tare Adjustment. This function can
be used for applications such as measuring the weight of the contents in a container by canceling the weight of the empty
container, or indicating the weight of each material adding into a container one after another.
With the I/O option code ‘6’ or ‘A’, the ZERO signal can execute or cancel Forced Zero and Tare Adjustment as well as the
front button control. The Forced Zero and Tare Adjustment control depends on the Forced Zero control lockout setting.
■
FORCED ZERO CONTROL (UP BUTTON) LOCKOUT
MAIN DISPLAY
FUNCTION
DEFAULT VALUE
Unlock Forced Zero and Tare Adjustment control
Unlock Forced Zero control / lock Tare Adjustment control
Lock Forced Zero and Tare Adjustment control
NOTE
The Forced Zero control lockout limits the Forced Zero and Tare Adjustment via the front button control, but does not limit
the control with the ZERO signal.
■
DISPLAY VALUE IN EXECUTING AND CANCELING FORCED ZERO AND TARE ADJUSTMENT
The display value changes as shown in the following figures when Forced Zero and Tare Adjustment are executed or
canceled with Up button. With the ZERO signal ON, the display changes likewise. Replace “Press (hold down) Up button”
with “Turn the ZERO signal ON”.
• Forced Zero control lockout ‘LV0’ (unlock Forced Zero and Tare Adjustment control)
(1) Press Up button to shift the present display value to zero (Forced Zero).
(2) Press Up button again to shift the display value to zero (Tare Adjustment).
(3) Hold down Up button for 1 second or more to cancel the Tare Adjustment mode. The display value is forced to 0 once.
(4) The display is back to the Forced Zero mode.
(5) Hold down Up button for 2 seconds or more to cancel the Forced Zero mode. The display value is forced to 0 once
(Tare Adjustment).
(6) Then the Tare Adjustment is canceled in approximately 1 second, and the Forced Zero is canceled in approximately 2
seconds.
Display value
Measured value
Forced Zero
executed
Tare Adjustment
executed
Tare Adjustment
executed
Tare Adjustment
canceled.
Back to Forced Zero.
Tare Adjustment
canceled.
Back to Forced Zero.
Tare Adj.
executed
Tare Adjustment
canceled.
Back to Forced Zero.
Tare Adjustment
canceled.
Back to Forced Zero.
Forced Zero
canceled
(1)
(2)
(3) (4)
(5)
(6)
Button pressed
Button pressed
Button
held
down
Button
held
down
1 sec.
1 sec.
2 sec.
Up
0