108
47DAC OPERATING MANUAL EM-9518-B Rev.4
3
Press Shift button to shift the display into the setting standby
mode. Then press Shift and Up buttons to set the LL (L, H, HH
or P) OFF delay time.
• The third digit starts blinking, to which you can apply changes.
• Set within the range of 000 to 999.
NOTE
The decimal point is not indicated. Set as ‘setting value × 100 milliseconds’.
4
Press Alarm/
↓
or Scale/
↑
button to apply the new setting.
• And the next parameter setting is indicated.
NOTE
• Press Alarm/
↓
button, and the LL (L, H, HH or P) one-shot output will be indicated (‘SHOT LL’, ‘SHOT L’, ‘SHOT H’,
‘SHOT HH’ or ‘SHOT P’ on the SD).
• Press Scale/
↑
button, and the LL (L, H, HH or P) ON delay time will be indicated (‘ONDLYLL’, ‘ONDLY L’, ‘ONDLY H’,
‘ONDLYHH’ or ‘ONDLY P’ on the SD).
5
■
TO GO ON TO SET ANOTHER OFF DELAY TIMES,
Repeat operation from Step 2.
■
TO SET THE NEXT PARAMETER,
Skip to Step 2 in “9.7 ONE-SHOT OUTPUT”.
■
TO QUIT,
Hold down Alarm/
↓
or Scale/
↑
button for 1 second or more to return to Measuring Mode.
Blinking