5.1 Operating with Auxiliary References
Frequency references can be configured with various calculated conditions that use
the main and auxiliary frequency references simultaneously. The main frequency
reference is used as the operating frequency, while auxiliary references are used to
modify and fine-tune the main reference.
Group
Code
Name
Setting
Setting Range
Unit
Operation
Frq
Frequency
reference source
0
Keypad-1
0
–8
-
bA
01
Auxiliary reference
source
1
V1
0
–4
-
02
Auxiliary command
calculation type
0
M+(G*A)
0
–7
-
03
Auxiliary frequency
reference gain
0.0
-200.0
–200.0
%
In
65
– 71
Px terminal setting
options
40 dis Aux Ref
0
–52
-
The table above lists the available calculated conditions for the main and auxiliary
frequency references. Refer to the table to see how the calculations apply to an
example where the Frq code has been set to 0 (Keypad-1), and the inverter is
operating at a main reference frequency of 30.00 Hz. Signals at -10
– +10 V are
received at terminal V1, with the reference gain set at 5%. In this example, the
resulting frequency reference is fine-tuned within the range of 27.00
–33.00 Hz [Codes
In.01
–16 must be set to the default values, and In.06 (V1 Polarity), set to 1 (Bipolar)].
Auxiliary Reference Setting Details
Code and
Features
Description
bA.01 Aux Ref
Src
Set the input type to be used for the auxiliary frequency reference.
Configuration
Function
0
None
Auxiliary frequency reference is disabled.
1
V1
Sets the V1 (voltage) terminal at the control terminal
block as the source of auxiliary frequency reference.
3
V0
Select the volume dial of keypad as auxiliary
command.
4
I2
Sets the I2 (current) terminal at the control terminal
block as the source of auxiliary frequency reference.
Summary of Contents for G100
Page 14: ......
Page 16: ...5 5 7 5 kW 3 Phase ...
Page 32: ...0 4 0 8 kW 1 5 2 2 kW 4 0 kW ...
Page 48: ......
Page 68: ......
Page 81: ......
Page 100: ......
Page 116: ...trips automatic Reset Restart is not attempted and the Fire Mode Count is not increased ...
Page 118: ......
Page 130: ... Terminal connections for 3 wire operation 3 wire operation ...
Page 140: ... PID control block diagram ...
Page 165: ...Code and Features Description Code Description continuous rating ...
Page 170: ......
Page 186: ... Displayed as on the Keypad ...
Page 200: ...provided signal output at 150 36 sec ...
Page 216: ...Code and Features Description delay time delay time ...
Page 219: ......
Page 237: ......
Page 253: ......
Page 295: ......
Page 314: ......
Page 335: ...Manual Revision History Revision History No Date Edition Changes 1 2019 01 First Release ...