Table 1. Server specifications (continued)
Specification
Description
RAID adapters (depending on
the model)
• SAS/SATA HBA adapters
– ThinkSystem 430-8i SAS/SATA 12Gb HBA
– ThinkSystem 430-16i SAS/SATA 12Gb HBA
– ThinkSystem 430-8e SAS/SATA 12Gb HBA
– ThinkSystem 430-16e SAS/SATA 12Gb HBA
– ThinkSystem 440-8i SAS/SATA PCIe Gen4 12Gb HBA
– ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb HBA
– ThinkSystem 440-16e SAS/SATA PCIe Gen4 12Gb HBA
• SAS/SATA RAID adapters
– ThinkSystem RAID 530-8i PCIe 12Gb Adapter
– ThinkSystem RAID 540-8i PCIe 12Gb Adapter
– ThinkSystem RAID 730-8i 1GB Adapter
– ThinkSystem RAID 730-8i 2GB PCIe Adapter
– ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
– ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
– ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter
– ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter
– ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter
– ThinkSystem RAID 940-16i 4GB Flash PCIe Gen4 12Gb Adapter
– ThinkSystem RAID 940-16i 8GB Flash PCIe Gen4 12Gb Adapter
– ThinkSystem RAID 5350-8i PCIe 12Gb Adapter
– ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb Adapter
– ThinkSystem RAID 9350-16i 4GB Flash PCIe 12Gb Adapter
Notes:
• RAID 730-8i 1G Cache SAS/SATA adapter is not available for North America.
• RAID 530-8i SAS/SATA adapter cannot be mixed with RAID 730-8i 1G Cache
SAS/SATA adapter.
• RAID 730-8i 2G Flash SAS/SATA adapter cannot be mixed with RAID 730-8i 1G
Cache SAS/ SATA adapter or RAID 930-8i SAS/SATA adapter.
• The RAID 940 adapters can be mixed with the ThinkSystem 440-8i SAS/SATA
PCIe Gen4 12Gb HBA and the ThinkSystem 440-16i SAS/SATA PCIe Gen4 12Gb
HBA.
• Mixing of RAID/HBA 430/530/730/930 adapters (Gen 3) and RAID/HBA 440/940
adapters (Gen 4) in the same system is not allowed.
• RAID 930/940 series or 9350 series adapters require a RAID flash power module.
• RAID 5350/9350 series adapters cannot be mixed with HBA/RAID 430/440/530/
730/930/940 series SAS/SATA adapters.
Fans
• One processor: three system fans (including one redundant fan)
• Two processors: four system fans (including one redundant fan)
Note:
If your server comes with only one processor, three system fans (fan 1 to fan
3) are adequate to provide proper cooling. However, you must keep the locations for
fan 4 occupied by a fan filler to ensure proper airflow.
5
Summary of Contents for ThinkSystem SR550
Page 1: ...ThinkSystem SR550 Maintenance Manual Machine Types 7X03 and 7X04 ...
Page 8: ...vi ThinkSystem SR550 Maintenance Manual ...
Page 49: ...Chapter 2 Server components 41 ...
Page 60: ...52 ThinkSystem SR550 Maintenance Manual ...
Page 113: ...Figure 80 Riser 1 assembly removal Chapter 3 Hardware replacement procedures 105 ...
Page 174: ...166 ThinkSystem SR550 Maintenance Manual ...
Page 192: ...184 ThinkSystem SR550 Maintenance Manual ...
Page 196: ...188 ThinkSystem SR550 Maintenance Manual ...
Page 200: ...192 ThinkSystem SR550 Maintenance Manual ...
Page 205: ......
Page 206: ......