Step 3. Press the release tab toward the handle and carefully pull the handle at the same time to slide the
hot-swap power supply out of the chassis.
Notes:
Slightly pull the power supply upwards when sliding the power supply out of the chassis, if
you have installed one of the following CMA kits:
• 2U CMA Upgrade Kit for Toolless Slide Rail
• Toolless Slide Rail Kit with 2U CMA
Figure 72. Hot-swap power supply removal
After removing the power supply:
• Install a power supply filler or a new power supply to cover the power supply bay.
Important:
To ensure proper cooling during normal server operation, both of the power supply bays must
be occupied. This means that each bay must have a power supply installed; or one has a power supply
installed and the other has a power supply filler installed.
• If you are instructed to return the old power supply, follow all packaging instructions and use any
packaging materials that are provided.
Install a hot-swap power supply
Use this information to install a hot-swap power supply.
Ground package before opening”
The following tips describe the type of power supply that the server supports and other information that you
must consider when you install a power supply:
• The standard shipping has only one power supply installed in the server. For redundancy and hot-swap
support, you must install an additional hot-swap power supply. Certain customized models might be
shipped with two power supplies installed.
.
Hardware replacement procedures
97
Summary of Contents for ThinkSystem SR550
Page 1: ...ThinkSystem SR550 Maintenance Manual Machine Types 7X03 and 7X04 ...
Page 8: ...vi ThinkSystem SR550 Maintenance Manual ...
Page 49: ...Chapter 2 Server components 41 ...
Page 60: ...52 ThinkSystem SR550 Maintenance Manual ...
Page 113: ...Figure 80 Riser 1 assembly removal Chapter 3 Hardware replacement procedures 105 ...
Page 174: ...166 ThinkSystem SR550 Maintenance Manual ...
Page 192: ...184 ThinkSystem SR550 Maintenance Manual ...
Page 196: ...188 ThinkSystem SR550 Maintenance Manual ...
Page 200: ...192 ThinkSystem SR550 Maintenance Manual ...
Page 205: ......
Page 206: ......