Figure 27. Cable routing for server models with sixteen 2.5-inch hot-swap drives, 16i adapter, and serial port module
Cable
From
To
1
SAS signal cable*
SAS 0 and SAS 1 connectors on the
backplane 1
HBA/RAID adapter installed in PCIe
slot 1:
• Gen 3: C0C1
• Gen 4: C0
2
SAS signal cable*
SAS 0 and SAS 1 connectors on the
backplane 2
HBA/RAID adapter installed in PCIe
slot 1:
• Gen 3: C2C3
• Gen 4: C1
3
Power cable
Power connector 1 on the backplane
Backplane power connector 1 on the
system board
4
Power cable
Power connector 2 on the backplane
Backplane power connector 2 on the
system board
Note:
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem
SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).
.