Table 13. Installation sequence of Ethernet adapters with RJ-45 connectors
Number of installed processor
PCIe slot
One processor
4, 2, 6, 3, 1
Two processors
4, 2, 6, 3, 5, 1
Install a PCIe adapter on the system board
Use this information to install a PCIe adapter on the system board.
Ground package before opening”
Before installing a PCIe adapter on the system board, touch the static-protective package that contains the
new PCIe adapter to any unpainted surface on the outside of the server. Then, take the new PCIe adapter out
of the package and place it on a static-protective surface.
Notes:
• Depending on the specific type, your PCIe adapter might look different from the illustration in this topic.
• Use any documentation that comes with the PCIe adapter and follow those instructions in addition to the
instructions in this topic.
To install a PCIe adapter on the system board, complete the following steps:
Watch the procedure
A video of this procedure is available at
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
Step 1. Locate the PCIe slot 4. If the slot is covered with a slot bracket, open the retention latch and
remove the slot bracket from the chassis. Store the bracket for future use.
Step 2. If the new PCIe adapter is installed with a full-height bracket, replace the full-height bracket with
the low-profile bracket by doing the following:
a. Carefully remove the screws that secure the PCIe adapter and then remove the full-height
bracket from the PCIe adapter.
b. Note the orientation and align the screw holes in the low-profile bracket with the
corresponding holes in the PCIe adapter. Then, install the screws to secure the bracket to the
PCIe adapter.
Step 3. Position the PCIe adapter near the PCIe slot. Then, carefully press the PCIe adapter straight into
the slot until it is securely seated and its bracket also is secured by the chassis.
114
ThinkSystem SR550 Maintenance Manual
Summary of Contents for ThinkSystem SR550
Page 1: ...ThinkSystem SR550 Maintenance Manual Machine Types 7X03 and 7X04 ...
Page 8: ...vi ThinkSystem SR550 Maintenance Manual ...
Page 49: ...Chapter 2 Server components 41 ...
Page 60: ...52 ThinkSystem SR550 Maintenance Manual ...
Page 113: ...Figure 80 Riser 1 assembly removal Chapter 3 Hardware replacement procedures 105 ...
Page 174: ...166 ThinkSystem SR550 Maintenance Manual ...
Page 192: ...184 ThinkSystem SR550 Maintenance Manual ...
Page 196: ...188 ThinkSystem SR550 Maintenance Manual ...
Page 200: ...192 ThinkSystem SR550 Maintenance Manual ...
Page 205: ......
Page 206: ......