To remove a hot-swap power supply, complete the following steps:
Watch the procedure
A video of this procedure is available at
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
Step 1. If the server is in a rack, adjust the cable management arm (CMA) to gain access to the power
supply.
If you have installed the ThinkSystem 2U CMA Upgrade Kit for Toolless Slide Rail or ThinkSystem
Toolless Slide Rail Kit with 2U CMA, do the following:
Figure 71. CMA adjustment
a. Press down the stop bracket
1
and rotate it to the open position.
b. Rotate the CMA out of the way to gain access to the power supply.
Step 2. Disconnect the power cord from the hot-swap power supply.
Note:
If you are replacing two power supplies, do the power supply replacement one by one to
ensure that the power supply to the server is not interrupted. Do not disconnect the power cord
from the secondly replaced power supply until the power output LED for the firstly replaced power
supply is lit. For the location of the power output LED, refer to “Rear view LEDs” on page 24.
96
ThinkSystem SR550 Maintenance Manual
Summary of Contents for ThinkSystem SR550
Page 1: ...ThinkSystem SR550 Maintenance Manual Machine Types 7X03 and 7X04 ...
Page 8: ...vi ThinkSystem SR550 Maintenance Manual ...
Page 49: ...Chapter 2 Server components 41 ...
Page 60: ...52 ThinkSystem SR550 Maintenance Manual ...
Page 113: ...Figure 80 Riser 1 assembly removal Chapter 3 Hardware replacement procedures 105 ...
Page 174: ...166 ThinkSystem SR550 Maintenance Manual ...
Page 192: ...184 ThinkSystem SR550 Maintenance Manual ...
Page 196: ...188 ThinkSystem SR550 Maintenance Manual ...
Page 200: ...192 ThinkSystem SR550 Maintenance Manual ...
Page 205: ......
Page 206: ......