
Malfunction, cause and remedy
17
Faults of the electrics/electronics
17.5
Comprima V 180
Original Operating Instructions 150001053_00_en
203
Following the stated references, you will get to the individual test steps of the possible error
causes. When all test steps have been processed and the error has still not been remedied, the
next possible cause must be checked or the next error in the error list of the terminal must be
remedied. The test steps do not contain the components to be tested in detail such as contacts,
plug designations etc. but must be selected by means of the circuit diagram.
520192-
KBT
KRONE operating terminal (KBT)
Possible cause
Remedy
FMI 19: There is a CAN communication malfunction.
The cabling is faulty.
Check the cabling for damage,
.
The operating terminal is de-
fective.
Note the error number with the FMI and contact the KRONE
service partner.
520193-
KBT
KRONE operating terminal (KBT)
Possible cause
Remedy
FMI 19: There is a CAN communication malfunction.
The cabling is faulty.
Check the cabling for damage,
.
The operating terminal is de-
fective.
Note the error number with the FMI and contact the KRONE
service partner.
520194-
KBT
KRONE operating terminal (KBT)
Possible cause
Remedy
FMI 19: There is a CAN communication malfunction.
The cabling is faulty.
Check the cabling for damage,
.
The operating terminal is de-
fective.
Note the error number with the FMI and contact the KRONE
service partner.
520195-
KBT
KRONE operating terminal (KBT)
Possible cause
Remedy
FMI 19: There is a CAN communication malfunction.
The cabling is faulty.
Check the cabling for damage,
.
The operating terminal is de-
fective.
Note the error number with the FMI and contact the KRONE
service partner.
520198-
EEPROM
EEPROM of KRONE Machine Controller (KMC)
Possible cause
Remedy
FMI 12: There is an internal error.
The control unit KMC is de-
fective.
Replace the control unit KMC.
Note the error number with the FMI and contact the KRONE
service partner.