16
Maintenance
16.22 Servicing compressed air brake (for version with "Compressed air brake")
190
Comprima V 180
Original Operating Instructions 150001053_00_en
16.21.3
Replacing the hose on the dosing unit
RP000-232
If hoses (4) on the dosing units (2) are damaged, they must be replaced.
ü
The machine is shut down and safeguarded,
.
ü
The front side hood is open.
Unscrew the cap nut (1) from the dosing unit (2).
Cut through the hose (4) above the cap nut (1).
ð
The hose (4) is shortened with each cut. Therefore, do not cut any further than the
piece which is damaged.
Pull the defective hose (4) out of the cap nut (1) and dispose of.
Screw the cap nut (1) onto the dosing unit (2) hand-tight.
Insert the new end of the hose (4). Ensure that the hose (4) has been completely inserted
into the cap nut (1).
16.22
Servicing compressed air brake (for version with "Compressed air
brake")
16.22.1
Cleaning air filter
3
4
5
6 7
2
8
1
RP000-436
1 Air filter complete
5 Spring
2 Spring
6 Seal ring
3 Filter element
7 Cover cap
4 Spacer
8 Clasp locking ring
The air filters (1) clean the compressed air and guard the compressed air brake from
malfunctions. The compressed air brake remains functional in both directions of flow even when
a filter element (3) is blocked.