Maintenance
16.21 Servicing central chain lubrication system
188
Comprima V 180
Original Operating Instructions 150001053_00_en
16.21
Servicing central chain lubrication system
16.21.1
Checking oil level, topping up oil and changing filter
1
2
3
4
5
7
6
RPG000-079
Checking oil level and topping up oil
Read off the oil level on the reservoir (3).
If the oil level is too low, top up the oil via the opening (4),
.
Bleeding central chain lubrication system
If the reservoir (3) is empty, the central chain lubrication system must be bled:
On the reservoir (3) top up the oil via the opening (4),
Remove the hose from the connection (6) of the pump (7) and wait until oil runs out.
When oil has run out, connect the hose to the pump (7).
Open the bleed screw (2).
Manually actuate the pump (7) until oil is flowing out of the control block (1) without any
bubbles.