![Krone Big Pack 1270 XC Original Operating Instructions Download Page 291](http://html1.mh-extra.com/html/krone/big-pack-1270-xc/big-pack-1270-xc_original-operating-instructions_2004793291.webp)
Maintenance - Gearbox
20
Gearbox knotter fan
20.6
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
291
BP000-260
Observe the safety routine “Safely performing oil level check, oil change and filter element
change”,
.
Checking oil level
Unscrew the locking screw of the inspection hole (1).
Æ
If the oil reaches the inspection hole (1):
Mount the locking screw of the inspection hole (1), tightening torque
Æ
If the oil does not reach the inspection hole (1):
Unscrew the locking screw of the filling hole (3).
Top up new oil via the filling hole (3) up to the inspection hole (1).
Mount the locking screw of the inspection hole (1) and the locking screw of the filling
hole (3), Tightening torque
.
Changing oil
ü
A suitable container is available for escaping oil.
Unscrew the locking screw of the inspection hole (1) and the locking screw of the filling hole
(3).
Unscrew the drain plug (2) and drain the oil.
Mount the drain plug (2), tightening torque
Top up new oil via the filling hole (3) up to the inspection hole (1).
Mount the locking screw of the inspection hole (1) and the locking screw of the filling hole
(3),Tightening torque
20.6
Gearbox knotter fan
For “knotter fan” version
INFORMATION
The oil level must be checked and changed with the machine in horizontal position. Use the
lower edges of the cross-members as a reference edge.