![Krone Big Pack 1270 XC Original Operating Instructions Download Page 295](http://html1.mh-extra.com/html/krone/big-pack-1270-xc/big-pack-1270-xc_original-operating-instructions_2004793295.webp)
Maintenance - Brake System
21
Checking compressed air reservoir
21.3
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
295
DVG000-014
Compressed air reservoir for “compressed air
brake” version
Compressed air reservoirs for knotter cleaning
Releasing pressure from the compressor unit
Shut down and safeguard the machine,
.
Activate the drain valve (2) on the compressed air reservoir (1) until the pressure has been
released.
Checking the compressed air reservoir
Have the interior area of the compressed air reservoir checked in accordance with national
requirements. A check is recommended at intervals of
2 years
.
21.3.1
Checking the drain valve
Shut down and safeguard the machine,
.
ü
A suitable container is available for escaping condensation water.
Open the drain valve (2) and allow the condensation water to run out.
Check and clean the drain valve (2) and screw it in again.
21.3.2
Tightening tensioning belts
Shut down and safeguard the machine,
.
Check the tensioning strap (3) for firm attachment.
If the tensioning straps are not taut, the setting is correct.
If the tensioning straps are not taut, they must be retightened.
Tensioning tensioning straps
In order to tension the tensioning straps, tighten the nuts.