Malfunction, cause and remedy
23
Malfunctions electrics/electronics
23.1
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
337
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522316-
H105
Actuator H105 “Horn twine box“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522317-
K30
Actuator K30 “Cleaning 2“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522318-
K29
Actuator K33 “Cleaning 1“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522319-
K05
Actuator K05 “Bale ejector plunger surface“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.