![Krone Big Pack 1270 XC Original Operating Instructions Download Page 345](http://html1.mh-extra.com/html/krone/big-pack-1270-xc/big-pack-1270-xc_original-operating-instructions_2004793345.webp)
Malfunction, cause and remedy
23
General malfunction
23.2
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
345
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
The wiring to KMC is faulty.
Check wiring for damage.
One or more sensors/actuat-
ors connected to the voltage
group are defective.
There is an overview of the position of the sensors,
actuators and control units in the circuit diagram,
Check sensor and wiring for damage,
.
The control unit is defective.
Replace the control unit.
23.2
General malfunction
Malfunction:
Plunger/tying unit stops.
Possible cause
Remedy
The cam clutch in the flywheel
is engaging again at a low
speed.
Stop the tractor immediately.
Reduce the baling force.
Check the rotational speed of the universally-jointed drive
shaft.
Pull the knotter needles out of the bale channel; if required
replace the shear bolt in the knotter and needle drive.
Malfunction:
The knotter needles fall back.
Possible cause
Remedy
The knotter shaft brake is set
too loose.
Retighten the knotter shaft brake.
Malfunction:
The big bales are not pressed densely enough.
Possible cause
Remedy
The force of pressure is too
low.
Increase the force of pressure.
Malfunction:
The big bales are pressed too tight.
Possible cause
Remedy
The baling force is too high.
Reduce the baling force.
Malfunction:
The packer does not move.
Possible cause
Remedy
The overload clutch slips.
Reduce the engine speed.
Shut down tractor and machine and remove the crop
blockage.
Reduce driving speed.
Malfunction:
Pick-up does not move.
Possible cause
Remedy
The overload clutch slips.
Shut down tractor and machine and remove the crop
blockage.
Reduce driving speed.
Drive over the swath centre.