Malfunction, cause and remedy
23
Malfunctions electrics/electronics
23.1
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
341
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522339-
K15
Actuator K15 “MultiBale“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522340-
K14
Actuator K14 “Entire bale“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522346-
K13
Actuator K13 “Cutting rotor safety valve“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522535-
RMC
Control unit moisture measurement (RMS)
Possible cause
Remedy
FMI 19: There is a network/CAN error.
The wiring is faulty.
Check wiring.
The control unit is defective.
Note the error number and the FMI. Then contact the
dealer.
522536-
RMC
Control unit moisture measurement (RMS)