![Krone Big Pack 1270 XC Original Operating Instructions Download Page 326](http://html1.mh-extra.com/html/krone/big-pack-1270-xc/big-pack-1270-xc_original-operating-instructions_2004793326.webp)
23
Malfunction, cause and remedy
23.1
Malfunctions electrics/electronics
326
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522107-
B 4
Sensor B4 “Plunger at rear (measuring)“
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522108-
B 5
Sensor B5 “Front plunger (calibrate)“
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522109-
B 1
Sensor B1 “Flywheel brake“
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522111-
B11
Sensor B11 “Bale chute“
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522112-
B19
R
Sensor B19 “Force sensor right“