![Krone Big Pack 1270 XC Original Operating Instructions Download Page 152](http://html1.mh-extra.com/html/krone/big-pack-1270-xc/big-pack-1270-xc_original-operating-instructions_2004793152.webp)
13
Terminal – Machine functions
13.14 Opening/closing bale channel flaps
152
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
Switching off
To switch off the starting aid, press
.
Æ
The display switches from
to
.
Æ
The starting aid is switched off.
13.14
Opening/closing bale channel flaps
Opening
Press
.
Æ
The display switches from
to
.
Closing
Press
.
Æ
The display switches from
to
.
13.15
Lower the bale chute
ü
The locking on the baling flaps is opened,
.
WARNING! Increased risk of injury! While the bale chute is being lowered, ensure that
there is nobody in the danger zone (particularly behind the machine). Press and hold
down
.
The bale chute is lifted/lowered by means of the external momentary switches.
13.16
Automatic bale ejection
To execute 10 bale ejections, press
again.
Æ
When the bale channel flaps are opened, 10 bale ejections are executed immediately.
Æ
When the bale channel flaps are closed, first the bale channel flaps are opened and then
10 bale ejections are executed.
13.17
Selecting "Counter/Detail counter" menu
Press
.
Æ
The "Detail counter" menu is displayed,