23
Malfunction, cause and remedy
23.1
Malfunctions electrics/electronics
300
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
520192
19
KBT
SPN (Suspect Parameter
Number) = error number
Icon
Acknowledging the error message
Note down the error message.
Briefly press
.
Æ
The acoustic signal stops and the error display disappears.
Eliminate the error,
.
If the fault occurs again, the error message will appear again.
Error messages that have already been acknowledged and error messages that are still
pending can be displayed again via the “Error list” menu (
).
23.1.1.1
Possible error types (FMI)
There are different types of errors which are shown under the term FMI (Failure Mode
Identification) with an appropriate code.
FMI
Meaning
0
The upper limit value was greatly exceeded.
1
The lower limit value was far below the required one.
2
The data is not permitted.
3
There is an overvoltage or a short circuit to supply voltage.
4
There is an undervoltage or a short circuit to ground.
5
A cable is broken or amperage is too low.
6
There is a short circuit to ground or amperage is too low.
7
The mechanics do not respond or the expected result was not achieved.
8
The frequency is not permitted.
9
There is an abnormal update rate.
10
There is an abnormal rate of change.
11
The error cause is unknown.
12
There is an internal error.
13
The values of the calibration are outside the value range.
14
Particular instructions are required.
15
The upper limit value has been reached.
16
The upper limit value has been exceeded.
17
The lower limit value has been reached.
18
The lower limit value has not been reached.
19
There is a CAN communication failure.