Malfunction, cause and remedy
23.1
Malfunctions electrics/electronics
314
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
Possible cause
Remedy
FMI 7: The mechanics do not respond or the expected result was not achieved.
The blade cassette is blocked.
522010-
Blade cassette is down
Possible cause
Remedy
FMI 7: The mechanics do not respond or the expected result was not achieved.
When the universal shaft is ro-
tating, the blade cassette is
down.
Raise the blade cassette.
522011-
Blade cassette is down
Possible cause
Remedy
FMI 2: The data is not permitted.
In "road travel" mode the
blade cassette is down.
Raise the blade cassette.
522012-
Blade cassette is down
Possible cause
Remedy
FMI 2: The data is not permitted.
When the machine is starting
up, the blade cassette is
down.
Raise the blade cassette.
522013-
S1
Momentary switch “Raise blade cassette"
Possible cause
Remedy
FMI 2: The data is not permitted.
The momentary switch is
sticking.
Eliminate the cause of the momentary switch sticking.
Replace the momentary switch.
522014-
S2
Momentary switch “Lower blade cassette"
Possible cause
Remedy
FMI 2: The data is not permitted.
The momentary switch is
sticking.
Eliminate the cause of the momentary switch sticking.
Replace the momentary switch.
522015-
>MAX
Baling flap pressure