Malfunction, cause and remedy
23.1
Malfunctions electrics/electronics
338
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
522320-
K06
Actuator K06 “Bale ejector annular surface“
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522321-
FMA1
Force measurement amplifier 1 (FMA 1) “Baling force control”
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
FMI 1: The lower limit value was far below the required one.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522322-
FMA1
Force measurement amplifier 1 (FMA 1) “Baling force control”
Possible cause
Remedy
FMI 0: The upper limit value was greatly exceeded.
FMI 1: The lower limit value was far below the required one.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522325-
H1
Actuator H1 „Working lights “ (rear left)
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522326-
H1
Actuator H1 „Working lights “ (rear right)
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.