Possible cause
Remedy
FMI 19: There is a network/CAN error.
The wiring is faulty.
Check wiring,
The operating terminal is de-
fective.
Note the error number and the FMI. Then contact the
dealer.
520195-
KBT
KRONE operating terminal (KOT)
Possible cause
Remedy
FMI 19: There is a network/CAN error.
The wiring is faulty.
Check wiring,
The operating terminal is de-
fective.
Note the error number and the FMI. Then contact the
dealer.
520198-
EEPROM
EEPROM of KRONE Machine Controller (KMC)
Possible cause
Remedy
FMI 12: There is an internal error.
The control unit KMC is de-
fective.
The control unit KMC is defective.
Note the error number and the FMI. Then contact the
dealer.
521100-
High
Voltage group (UB1) of the KRONE Machine Controller (KMC)
Possible cause
Remedy
FMI 3: There is a short circuit or an overvoltage.
The cabling is faulty.
Check the cabling for damage,
.
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram,
Check the sensor and cabling for damage,
The control unit KMC is de-
fective.
Replace the control unit KMC.
521100-
Low
Voltage group (UB1) of the KRONE Machine Controller (KMC)
Possible cause
Remedy
FMI 4: There is a cable break/short circuit, general error or undervoltage.
The cabling is faulty.
Check the cabling for damage,
.
One or several sensors/actu-
ators connected to the voltage
group are defective.
An overview of the position of the sensors, actuators and
control units is provided in the circuit diagram,
Check the sensor and cabling for damage,
The control unit KMC is de-
fective.
Replace the control unit KMC.