Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522150-
B20
Sensor B20 “Pick-up speed“
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522157-
B 9
Sensor B9 „Needle connecting rod left“
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522160-
B33
Sensor B33 “Blade cassette inactive“
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522162-
B32
Sensor B32 “Blade cassette active“
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
.
The sensor wiring is faulty.
522231-
B21
Sensor B21 "Position MultiBale"