![Krone Big Pack 1270 XC Original Operating Instructions Download Page 146](http://html1.mh-extra.com/html/krone/big-pack-1270-xc/big-pack-1270-xc_original-operating-instructions_2004793146.webp)
13
Terminal – Machine functions
13.3
Displays on the working screen
146
BiG Pack 1270 XC
Original Operating Instructions 150000748_01_en
Icon
Designation
Explanation
94 /
240
cm
Bale length display
• The black value and the bar indicate the
current bale length.
• The blue value and the red mark
indicate the set target bale length.
• The blue value is touch-sensitive.
Baling flap pressure
• In manual mode.
• In bar or PSI (depending on selected
system of units).
• The black value under the bar display
and the bar indicate the current baling
flap pressure.
• The blue value under the bar display
and the red marking indicate the set
target baling flap pressure.
• The blue value is touch-sensitive.
Baling force as %
• In automatic mode.
• Display for the baling force on the right
and left in the bale channel.
• The black value under the bar display
and the bar indicate the current baling
force.
• The blue value under the bar display
and the red mark indicate the set target
baling force.
• The display may fluctuate considerably.
The control only functions when the
packer is supplying crops to the piston.
• The bale channel flap pressure is
automatically set by the system based
on the measured plunger force.
• The blue value is touch-sensitive.
Flywheel brake applied
Blade cassette not up
Knot run
• Is displayed briefly after a knot is tied.
• When the knotter signal is activated, a
horn sounds for approx. 1 s,
Bale ejector active
Self-steering axle locked
Warning beacon switched
on
Warning beacon switched
off