164
4.4 Error Code
REGIUS MODEL 190 Service Manual Ver.1.00 2004.11.01
12205
Internal error
Network com-
munication
Net Command Tim-
eout
Open and close the door and then
restore. If restoration is not possible,
restart.
12206
Internal error
Network com-
munication
Transfer End Time-
out
Open and close the door and then
restore. If restoration is not possible,
restart.
12210
Internal error
Network com-
munication
Resent counts
Over
fl
ow
Open and close the door and then
restore. If restoration is not possible,
restart.
12211
Internal error
Network com-
munication
CRC Error counts
Over-
fl
ow
Open and close the door and then
restore. If restoration is not possible,
restart.
13000
Main control error
H sync timeout
No H-SYNC signal is received. Con-
fi
rm H-sync signal . Con
fi
rm whether
the laser is ON. "
2.6.5 Checking H-
sync Signal, p.80"
13001
Main control error
Polygon Timeout
Con
fi
rm whether the laser is on. If so,
a polygon is abnormal.
13030
Main control error
DMA Timeout
Open and close the door and then
restore. If restoration is not possible,
restart.
13031
Main control error
SCOM Timeout
Open and close the door and then
restore. If restoration is not possible,
restart.
14000
Signal process error
Gain Over
fl
ow
The gain value has been incorrectly
set. Carry out
fi
xed-current reading
and con
fi
rm the operation of the
ADB2. If the
fi
xed current is correct,
carry out a restart. If a problem is
identi
fi
ed, replace the ADB2.
14001
Signal process error
Gain Under
fl
ow
The gain value has been incorrectly
set. Carry out
fi
xed-current reading
and con
fi
rm the operation of the
ADB2. If the
fi
xed current is correct,
carry out a restart. If a problem is
identi
fi
ed, replace the ADB2.
14002
Signal process error
Offset Over
fl
ow
The offset value has been incorrectly
set. Carry out
fi
xed-current reading
and con
fi
rm the operation of the
ADB2. If the
fi
xed current is correct,
carry out a restart. If a problem is
identi
fi
ed, replace the ADB2.
14003
Signal process error
Offset Under
fl
ow
The offset value has been incorrectly
set. Carry out
fi
xed-current reading
and con
fi
rm the operation of the
ADB2. If the
fi
xed current is correct,
carry out a restart. If a problem is
identi
fi
ed, replace the ADB2.
Code
Medium Classifi-
cation
Detailed Clas-
sification
Countermeasures, etc.
Summary of Contents for REGIUS 190
Page 7: ...VI REGIUS MODEL 190 Service Manual Ver 1 00 2004 11 01...
Page 13: ...Blank...
Page 27: ...xx REGIUS MODEL 190 Service Manual Ver 1 00 2004 11 01...
Page 28: ...Chap 1 Overview...
Page 29: ...Blank Page...
Page 43: ...16 1 3 Layout of Controlling Components REGIUS MODEL 190 Service Manual Ver 1 00 2004 11 01...
Page 45: ...Blank Page...
Page 52: ...Chap 2 Disassembly and Reassembly...
Page 53: ...Blank Page...
Page 118: ...Chap 3 Maintenance Adjustment...
Page 119: ......
Page 154: ...Chap 4 Troubleshooting...
Page 155: ......
Page 194: ...A Appendix...
Page 195: ......
Page 220: ...0676 55030 B 0412TE...