Chapter 3 Troubleshooting
3-5
3.2
Description of the Error Codes and How to Respond
3.2.1 06000 ~ 06037: Justifier Motor Errors
•
Error codes S column: Errors at the read operation/calibration.
•
Error codes E column: Errors during erase operation.
•
Error codes I column: Errors during initialization.
Error code
Description of the error
Response
(References to replacement methods are
listed at the end of the table.)
S
E
I
06000 06015 06030
Justifier HP sensor error
(when moving to HP)
Justifier HP sensor did not go
ON when the justifier guide was
moving to the home position.
Confirm following and replace the faulty parts.
•
Justifier HP sensor
•
Sensor wire: JP41 ~ MCN3 (MDU)
•
Justifier motor
•
Motor wire: JJ50 ~ MCN5 (MDU)
•
MDU
06001 06016 06031
Justifier motor control error
(when moving to HP)
There was a trouble with the motor
control when the justifier guide
was moving to the home position.
Confirm following and replace the faulty parts.
•
Justifier motor
•
Motor wire: JJ50 ~ MCN5 (MDU)
•
MDU
06002 06017 06032
Justifier HP sensor error
(when moving to cassette
fixing position)
Justifier HP sensor did not go
OFF when the justifier guide
was moving to the cassette
fixing position.
Confirm following and replace the faulty parts.
•
Justifier HP sensor
•
Sensor wire: JP41 ~ MCN3 (MDU)
•
Justifier motor
•
Motor wire: JJ50 ~ MCN5 (MDU)
•
MDU
06003 06018 06033
Justifier motor control error
(when moving to cassette
fixing position)
There was a trouble with the motor
control when the justifier guide was
moving to the cassette fixing position.
Confirm following and replace the faulty parts.
•
Justifier motor
•
Motor wire: JJ50 ~ MCN5 (MDU)
•
MDU
06004 06019 06034
Justifier motor control error
(when moving to minute
opening position)
There was a trouble with the motor
control when the justifier guide was
moving to the minute opening position.
06005 06020 06035
Justifier motor control error
(when moving to cassette fixing
position 2)
There was a trouble with the motor
control when the justifier guide was
moving to the minute opening position.
06006 06021 06036
Justifier HP sensor error
(when moving to HP 2)
Justifier HP sensor did not go
ON when the justifier guide was
moving from the cassette fixing
position to the home position.
Confirm following and replace the faulty parts.
•
Justifier HP sensor
•
Sensor wire: JP41 ~ MCN3 (MDU)
•
Justifier motor
•
Motor wire: JJ50 ~ MCN5 (MDU)
•
MDU
06007 06022 06037
Justifier motor control error
(when moving to HP 2)
There was a trouble with the motor
control when the justifier guide was
moving from the cassette fixing
position to the home position.
Confirm following and replace the faulty parts.
•
Justifier motor
•
Motor wire: JJ50 ~ MCN5 (MDU)
•
MDU
Summary of Contents for 0902
Page 2: ......
Page 6: ......
Page 12: ......
Page 30: ...2 10...
Page 54: ......
Page 84: ...Chapter 3 Troubleshooting 3 30 3 2 19 Confirm the H sync Signal To be stated...
Page 85: ...Chapter 3 Troubleshooting 3 31 3 2 20 Confirm the LMC Operation To be stated...
Page 120: ......
Page 296: ...8 10...
Page 300: ......
Page 301: ......