Chapter 5 Disassembly and Assembly
5-105
6
Remove the circuit board mount bracket.
•
2 hex/Phillips-head screws (M4 x 8)
7
Remove the standby power supply.
•
2 hex/Phillips-head screws (M3 x 6)
8
Install the new standby power supply.
•
2 hex/Phillips-head screws (M3 x 6)
9
See
to install the circuit board mount
bracket.
•
2 hex/Phillips-head screws (M4 x 8)
10
Connect the cables removed in
standby power supply.
•
CN1 (JP23: cable)
•
CN2 (JP26: cable)
11
Install the interlock relay 2 that was removed in
•
2 screws (M4 x 6)
12
Install the snap ties that was removed in
13
Install the electric component mount panel that
was removed in
•
8 hex/Phillips-head screws (M4 x 8)
14
Installation Procedures (Page 5-8)"
"5.2.3 Removing/Installing the Exterior Panel
to install the first front panel.
Now, you have finished with the procedures to replace the standby power supply.