Chapter 4 Confirming Operation Using Service Tool
4-8
4.4
Confirming by Step Operation
Procedure to confirm the operation by step operation is described here.
1
Click the [Monitoring] tab in the [Unit Test] screen.
[Monitoring] panel is displayed.
2
Select the cassette used to perform the step
operation in the [Cassette Type].
Select [Cassette] when the actual cassette is to be
used.
Select the cassette size to be emulated if the actual
cassette is not used.
Important
You can not terminate the process half-way between the steps. Perform all the way to the last
step. To stop half-way between the steps, perform following steps to force quit the process.
1. Open the second front door.
(Remove the key if you are using the interlock release key.)
2. Remove the cassette if it is still in the equipment.
3. Close the second front door.
(Insert the key if you are using the interlock release key.)
4. Click the [Return] button on the "Unit Testî screen.
Note
Step operation is different from normal read action in the following points.
•
Vibration halt delay action will not be performed.
•
Laser does not come on, and PMT high voltage value is 0 V.
•
Subscan speed for reading direction is fixed to 175µm read.
•
Reading and transmission of image will not be performed.
•
Subscan speed for erasing direction is fixed to quick erase.
•
Erase lamp will not come on.
Summary of Contents for 0902
Page 2: ......
Page 6: ......
Page 12: ......
Page 30: ...2 10...
Page 54: ......
Page 84: ...Chapter 3 Troubleshooting 3 30 3 2 19 Confirm the H sync Signal To be stated...
Page 85: ...Chapter 3 Troubleshooting 3 31 3 2 20 Confirm the LMC Operation To be stated...
Page 120: ......
Page 296: ...8 10...
Page 300: ......
Page 301: ......