Chapter 3 Troubleshooting
3-41
3.4.4 Horizontal Streak in Part of the Image
Phenomenon: Streak appears in part of the image
Phenomenon: Streak reaching sideways from a shielding material such as lead
Phenomenon: Density jump occur at about 30 mm from the top of image.
Phenomenon: Cyclic slanted streaks
Important
Always perform the image size adjustment, the image position adjustment, the unevenness
calibration, and the sensitivity calibration after replacing the optical unit.
No.
Cause
1
External force was applied during the read.
No.
Response
1
Perform read again making sure no shock is applied
to the equipment.
No.
Cause
1
It could happen when there are shielding material is
located at the white area.
No.
Response
1
•
Cause is so limited, ask the user to respond by
methods such as moving the shielding material
away from the object as much as possible or
decrease the exposure field.
•
Communicate the contact if it recur.
No.
Cause
1
Plate is in contact with the detach detection roller
due to warp or detach of the plate.
No.
Response
1
•
Return the plate with the warp or detach to the
contact.
•
Adjust the detach detection roller when it occurs
in multiple plates.
No.
Cause
Response
1
There is a possibility that light is entering
from outside.
Confirm by reading solid image after reattaching the
exteriors, or darkening the room.
Summary of Contents for 0902
Page 2: ......
Page 6: ......
Page 12: ......
Page 30: ...2 10...
Page 54: ......
Page 84: ...Chapter 3 Troubleshooting 3 30 3 2 19 Confirm the H sync Signal To be stated...
Page 85: ...Chapter 3 Troubleshooting 3 31 3 2 20 Confirm the LMC Operation To be stated...
Page 120: ......
Page 296: ...8 10...
Page 300: ......
Page 301: ......