Chapter 5 Disassembly and Assembly
5-96
9
See
to install the locking pin unit
assembly.
•
Noise filter
•
2 screws (M4 x 8)
•
Grounding cable: 1 screw (M4 x 8)
•
Circuit protector unit assembly
•
2 screws (M4 x 8)
Move the noise filter in the direction of the arrow in the
figure and fix it.
10
See
to install the exterior frame (right).
•
A: 4 hex/Phillips-head screws (M4 x 8)
•
B: 12 screws (M4 x 8)
11
See
to connect the grounding cable of the
inlet to the frame.
•
1 hex/Phillips-head screw (M5 x 10)
12
Connect the connector (JP1) that was removed in
13
Connect the CIU connector (CN5) that was
removed in
•
CN5 (CCN5: cable)
14
Connect the cooling fan connector (JJ62) that
was removed in
15
Installation Procedures (Page 5-8)"
"5.2.3 Removing/Installing the Exterior Panel
to install the insertion unit and exterior panel.
Now, you have finished with the procedures to replace the noise filter and the circuit protector unit.
Caution
After installing, make sure that circuit
protector has been switched to OFF.