7.2.4 Removal of Exterior Panels and Insertion Unit
Remove the exterior panels and the insertion unit to access the maintenance area.
1
Remove the second front back panel.
•
6 screws (M4 x 8)
•
1 spacer each (for 4 locations excluding the middle)
2
Remove the first front back panel.
•
7 screws (M4 x 8)
Remove the panel with both hands, holding on the
bottom and pulling away from the equipment.
3
Remove the first front panel.
•
6 screws (M4 x 8)
Remove the panel with both hands, holding on the
bottom and pulling away from the equipment.
4
Remove the circuit board cover.
•
3 screws (M3 x 6)
Loosen all.
Second Front Back Side
First Front Back Side
First Front Side
First Front Back Side