Chapter 5 Disassembly and Assembly
5-30
10
Install the shutter unit assembly that was
removed in
•
5 tapping screws (M4 x 10)
Press it in a direction of the arrow shown in the figure
to fix it.
11
Use a 0.2 mm-spacer (film) to check the clearance
between the lock cam and the stopper block.
If the clearance is any other value than 0.2 mm, adjust
the position of the stopper block.
12
Connect the cables that were unplugged in
to the shutter unit assembly.
•
Connector (JP20): shutter motor
•
Connector (JP35): shutter close detection sensor
•
Connector (JP36): shutter open detection sensor
•
Grounding cable: 1 hex/Phillips-head screw (M5 x 10)
13
Installation Procedures (Page 5-8)"
"5.2.3 Removing/Installing the Exterior Panel
to install the insertion unit and exterior panel.
Now, you have finished with the procedures to replace the insertion slot detection sensor (LPB).
0.2mm
JP20
JP35
JP36
Grounding Cable
Caution
Always attach the grounding cable in the
direction shown in the figure.