TRIGger:ACQuire:CURRent:SLOPe POSitive|NEGative, (@<chanlist>)
TRIGger:ACQuire:CURRent:SLOPe? (@<chanlist>)
TRIGger:ACQuire:VOLTage:SLOPe POSitive|NEGative, (@<chanlist>)
TRIGger:ACQuire:VOLTage:SLOPe? (@<chanlist>)
Sets the slope of the signal. Applies when the measurement trigger source is set to a level.
POSitive specifies a rising slope of the output signal.
NEGative specifies a falling slope of the output signal.
Parameter
Typical Return
POSitive|NEGative, *RST POSitive
POS or NEG
Sets the current slope to falling edge: TRIG:ACQ:CURR:SLOP NEG, (@1)
Sets the voltage slope to falling edge: TRIG:ACQ:VOLT:SLOP NEG, (@1)
TRIGger:ACQuire:TOUTput[:ENABle] 0|OFF|1|ON, (@<chanlist>)
TRIGger:ACQuire:TOUTput[:ENABle]? (@<chanlist>)
Enables measurement triggers to be sent to a digital port pin. The digital port pin must be configured
as trigger output before it can be used as a trigger source (see
).
Parameter
Typical Return
0|OFF|1|ON, *RST OFF
0 or 1
Enable sending measurement triggers to digital pins: TRIG:ACQ:TOUT ON, (@1)
TRIGger:ACQuire:SOURce <
source
>, (@<chanlist>)
TRIGger:ACQuire:SOURce? (@<chanlist>)
TRIGger:ARB:SOURce <
source
>
TRIGger:ARB:SOURce? (@<chanlist>)
TRIGger:DLOG:SOURce <
source
>
TRIGger:DLOG:SOURce? (@<chanlist>)
TRIGger:ELOG:SOURce <
source
>, (@<chanlist>)
TRIGger:ELOG:SOURce? (@<chanlist>)
TRIGger:HISTogram:SOURce <
source
>, (@<chanlist>)
TRIGger:HISTogram:SOURce? (@<chanlist>)
TRIGger:TRANsient:SOURce <
source
>, (@<chanlist>)
TRIGger:TRANsient:SOURce? (@<chanlist>)
TRIGger:ACQuire:SOURce - selects the trigger source for the acquisition system.
TRIGger:ARB:SOURce - selects the trigger source for the arbitrary waveform generator.
TRIGger:DLOG:SOURce - selects the trigger source for internal data logging.
TRIGger:ELOG:SOURce - selects the trigger source for external data logging.
TRIGger:HISTogram:SOURce - selects the trigger source for the current histogram.
TRIGger:TRANsient:SOURce - selects the trigger source for the transient system.
7 SCPI Programming Reference
340
Keysight N6705C Operating and Service Guide
Summary of Contents for N6705C
Page 76: ......
Page 353: ...Status Diagram Keysight N6705C Operating and Service Guide 353 7 SCPI Programming Reference ...
Page 376: ...8 Verification and Calibration 376 Keysight N6705C Operating and Service Guide ...
Page 389: ...Keysight N6705C Operating and Service Guide 389 8 Verification and Calibration ...
Page 434: ......
Page 438: ...9 Service and Maintenance 438 Keysight N6705C Operating and Service Guide ...
Page 460: ...9 Service and Maintenance 460 Keysight N6705C Operating and Service Guide ...
Page 461: ...Keysight N6705C Operating and Service Guide 461 9 Service and Maintenance ...
Page 462: ...9 Service and Maintenance 462 Keysight N6705C Operating and Service Guide ...
Page 463: ...Keysight N6705C Operating and Service Guide 463 9 Service and Maintenance ...
Page 470: ...Mezzanine Parts 9 Service and Maintenance 470 Keysight N6705C Operating and Service Guide ...
Page 471: ...Front Panel Parts Keysight N6705C Operating and Service Guide 471 9 Service and Maintenance ...
Page 476: ......